Change Over Switch Electric Change Over Switch

Product Details
Customization: Available
Warranty: 1 Year
Brand: Xhwellspec
Still deciding? Get samples of US$ 19.5/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Change Over Switch Electric Change Over Switch
  • Change Over Switch Electric Change Over Switch
  • Change Over Switch Electric Change Over Switch
  • Change Over Switch Electric Change Over Switch
  • Change Over Switch Electric Change Over Switch
  • Change Over Switch Electric Change Over Switch
Find Similar Products
  • Overview
  • Product Description
  • Company Information
  • Our Services
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
XHQ2-63/2P 63A
Operation
Rotating Handle
Certification
CCC, CE, ISO9001
Type
Integrated automatic transfer switch
Poles
2P
Output type
Dual
Rated Current
32/40/63A
Rated Voltage
AC 400V 50/60Hz
Working Voltage
AC 220-240V 50/60Hz
Withstand The Impact Voltage
1kv
Screen Function
Indicator Light
Transfer Time
≤3ms
ATS Class
CB
Operating Mode
Auto and Manual
Standard
IEC947-6-1, GB14048.11
Certificate
CE(LVD-2014/35/EU+EMC-2014/30/EU)
Transport Package
Standard Export Carton
Specification
40X33X30cm
Trademark
XHWellSpec
Origin
Zhejiang, China
HS Code
8536300000
Production Capacity
500000pieces Per Year

Packaging & Delivery

Package Size
20.00cm * 20.00cm * 20.00cm
Package Gross Weight
0.500kg
Lead Time
14 days (1 - 1 Pieces)
To be negotiated ( > 1 Pieces)

Product Description

Product Description

1. Application:

Mainly the transfer switch can be used as circuit control switch, test equipment switch, motor control switch and main command control switch, and transfer switch for electric welding machine, etc.The transfer switch is generally used for converting electrical control lines and electrical measuring instruments in AC 50HZ, DC 220V and below circuits with voltage up to 380V and below.For example, XHQ2-63 conversion switches are commonly used to convert and measure three-phase voltages.The combination switch is suitable for AC 50HZ, voltage up to 380V and below, DC voltage up to 220V and below. It is used to manually switch on or off the circuit infrequently, replace the power supply or load, and the carrying current is generally large.

 

2. Features: 

A. Small size but high switching capacity.

B. Built-in high performance MCU provides precise transfer power supply.

C. Energy-saving, driven by instantaneous impulse coil.

D. Cost-effective, improved circuit design consumes very low power.

E. Flame retardant cover provides good fire, heat and weather resistance.

F. Withstand the impact voltage: 1KV. 

3. Electrical Parameters 

Items Specifications
Model XHQ2-63/ 2P 63A
Rated Current 32/40/63A
Frequency 50/60Hz
Rated Voltage AC 400V 50/60Hz
Working Voltage AC 220-240V 50/60Hz
Screen Function Indicator Light
Transfer Time ≤30ms
ATS Class CB
Operating Mode Auto and Manual
Usage Grade AC-33iB
Transfer Way Automatic switching and reset
Insulation Voltage 800V
Withstand the Impact Voltage 1kV
Warranty 1 Year
Efficiency 97%
Electrical Life 100K times at least
Standard IEC947-6-1, GB14048.11
Outline Size 150mm X 138mm X 115mm
Weight 1450g
Certificate  CE, ISO

  

XHQ2-63/2P 32A Switch low voltage switches with multiple circuits.Multiple moving contacts are overlapped on the shaft. When the shaft rotates, moving contacts are connected or broken with static contacts in turn to switch circuits.An electrical appliance that changes a circuit from one set of connections to another.  

  

4. Testing Items:

Accelerated aging test; 

Inductive Voltage Test, DC Resistance Test, Safety Test etc.

5. Operating Instruction:

Change Over Switch Electric Change Over SwitchChange Over Switch Electric Change Over SwitchChange Over Switch Electric Change Over SwitchChange Over Switch Electric Change Over SwitchChange Over Switch Electric Change Over Switch

Company Information

 Change Over Switch Electric Change Over SwitchChange Over Switch Electric Change Over SwitchChange Over Switch Electric Change Over Switch
Change Over Switch Electric Change Over Switch

Our Services

 Change Over Switch Electric Change Over Switch

Packaging & Shipping

 Change Over Switch Electric Change Over Switch

  
FAQ

 

1. Working Conditions:

A. Ambient air temperature: -5oC~+40oC, the highest monthly mean temperature should not exceed +35oC;

B. Altitude for installing place should not exceed 2000m; 

C. Atmospheric relative humidity: + 40 not more than 50%, the highest humidity is 90%, air relative humidity of 85% or less;

D. Pollution level: level 2;

E: Use category: AC-22A;

F: Installation: install rail with TH35-7.5 profile steel, shall not exceed 5 degrees of vertical inclination.

 

2. Quality Assurance of Our Change Over Switch:

A. The main materials used in our change over switch are the high speed, tiny chip and low power consumption CPU as its' center processor inside and assembling with magnetic latching relay as its' main circuit and produced in a high standard of modularized design.

B. The protector will automatically connect circuits as designed time when its' voltage recovery to normal and ensures the terminal equipment runs well under unmanned operation mode.

C. The green indicator LED display lights when the power returns to normal and the red indicator LED display lights when the power is over, under normal voltage range or in delayed conditions.

 

3. Matters Need Attention:

A. This protector does not have overcurrent protection or short circuit protection, so it shall be installed in front of the protector with overcurrent protection and short circuit breaker;

B. When the protector is disconnected, the relay inside just cuts off L fire line, but N zero line is not broken, so L fire line and N zero line shall not be misconnected when it's in application;

C. Tighten the thread screw when assembling on unit for preventing damage to the product due to poor contact.

 

4. Why choose us:

A. We are reliable Alibaba Gold Supplier.

B. We are leading manufacturer in voltage protectors for more than 5 years' experience.

C. Rich experience in Global market, export to more than 50 countries.

D. 100% QC inspection before shipment.

E. Keep research and development the latest technology.

F. Reply within 24 hours.

G. After sale service: Professional technical support.

H. Customized design: We can produce according to your request.