Customization: | Available |
---|---|
Type: | Power Source Arrester |
Structure: | Zinc Oxide Arrester |
Still deciding? Get samples of US$ 34/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Citel, dehn, series, spd 20, Surge protector, surge protection devices, lightning protection system, spd, power surge protector, lightning protection, power strip surge protector, surge protector device, dc spd, 40ka surge protector, cable tv surge protector, whole house surge protector, ge power strip surge protector, spd 30, rj11 surge protector, surge protection, dc surge protection device, suntree spd, flexible surge protector, ac spd, lightning protection equipment, three phase lightning protector
1. Application:
The Citel SPD thunder protector surge citel surge protector is designed in parallel module, flame-retardant shelland nice sealing performance. The product has remote signal interface and fault indicating. It can be installed in the 35mm DIN rail and easy for wire installing. It is produced with the temperature control circuit technology according to IEC standard, it has over current breaker and thermal fuse circuit breaker and can be automatic tripped when it's deteriorated. We have different specifications in production and we can ensure satisfying for all kinds of demand, easy for maintenance and meet all working voltage levels and lightning discharge current, also we can customize for 220/380V power supply distribution system in lightning protection for various customer requirements.
2. Features:
A. High energy surge protection;
B. Pluggable replacement module;
C. Standard modular installation;
D. Reaction rate: 10-9 sec;
E. The built-in flash interrupter device;
F. Remote alarm interface;
G. The maximum discharge current of single module is 20~80kA (8/20μs);
H. Failure detection indicator.
omzn electric, electric in china,voltage protection device,citel,spd clas b c,thunder protector surge,surge protection devices 10ka,protectores de voltage para nevera,protector voltage,solar surge arrestor,voltage protector for refrigerator,tv guard voltage protection,citel spd,suntree,suntree solar, spd, Dehn spd, electric, price list mccb , tomzn, , electric in china, citel, lightning strike counter, citel spd, fridge guard, citel surge protector, tv guard, surge protection, protector de sobretensin citel, lightning counter, tv guard voltage protection, surge protection device, suntree solar, surge counter, citel surge protection suppliers, surge protection , imanes para refrigerador, lightning protection system, rv surge protector, voltage stabilizer, voltage protector for refrigerator, refrigerador, lightning arrester counter, spd, surge protector, spd suntree, rj45 surge protector, spd 30, protector de voltaje, phoenix surge, refrigerator voltage protector, surge protection devices rj45, high voltage protector, protector de voltaje 220, protector de voltaje 110, surge protector , tv voltage protector, spd , electric suntree, lipo under voltage protection, strike counter, voltage protector tomzn, rj45 surge protection spd, refrigerator household, spd dc, lightning protection, surge protector device, surgeprotectordevice, rj11 surge protector, voltage protection device, electric voltage protector, whole house surge protector, lightning counter for arrester, refrigerator protector, over voltage protection
3. Electrical Parameters
Model | XH36CIT-40 4P | XH36CIT-80 4P | XH36CIT-100 4P | XH36CIT-160 4P | ||||
Technical Parameters | ||||||||
IEC Class | Class I, Class | |||||||
Rated Voltage Un(V~) | 230V 60Hz | |||||||
Nominal Discharge Curreni ln( 8/20μs) | 20kA | 40kA | 60kA | 80kA | ||||
Max. Discharge Current( lmax) | 40kA | 80kA | 100kA | 160kA | ||||
Max. Continuous Operating Voltage Uc( V~) | 275V/320V/385V/440V Optional for Customized | |||||||
Voltage Protection Level(Up) | ≤2.0kV | ≤2.2kV | ≤2.4kV | ≤2.6kV | ||||
Equipped with Front Fuse | 40A | 80A | 100A | 125A | ||||
Protection Rating | IP20 | |||||||
Flame Retardant Rating | UL94 V-0 | |||||||
Response Time tA | <25ns | |||||||
Standard Compliance | IEC61643-11, GB/T18802.11 | |||||||
Operating Temperature | -40~+85 | |||||||
Relative Humidity | ≤95%(25) | |||||||
Installation | Standard DIN Rail 35mm(EN50022/DIN46277-3) | |||||||
Color and Outside Shape | Gray, Black, Red and Customized | |||||||
Failure Indication | Green: Normal, Red: Invalid | |||||||
Cross-sectional Area | 1.5mm²~25mm² Solid/35mm² Flexible | |||||||
Housing Material | PBT | PA66 | PA66 | PA66 |
Adopting Class I SPD to combine "1+1" circuit for protecting low voltage equipment from surge damages. It is applied in TT system and produced according to IEC61643-11/GB18802.11 standard. Our SPD is,
A. Green light indicates normal and red light indicates fault for operation;
B. Built-in circuit breaker and thermal disconnection device, the thermal disconnection device will cut off the SPD from the power line when fault occurs.
C. Impulse counter function records the lightning events.
D. External wiring terminal, easy for wiring and suitable for indoor application.
4. Dimensions and Wiring:
1. Working Conditions:
A. Ambient air temperature: -40oC~+85oC, the highest monthly mean temperature should not exceed +35oC;
B. Altitude for installing place should not exceed 2000m;
C. Atmospheric relative humidity: + 40 not more than 50%, the highest humidity is 95%, air relative humidity of 85% or less;
D. Pollution level: level 2;
E: Use category: AC-22A;
F: Installation: install rail with Standard DIN Rail 35mm(EN50022/DIN46277-3), shall not exceed 5 degrees of vertical inclination.
2. Quality Assurance of Our Surge Protective Device:
A. Guarantee for Replacement: during the warranty period, if there is any quality problem caused by the manufacturer, the user can go to the dealer to replace the products free of charge (if the appearance is damaged, it will be guaranteed);
B. Warranty service: if there is any quality problem with the products within the warranty period, users can enjoy the warranty service at the local after-sales service center; Local no after-sales service center, users can entrust dealers for warranty services;
C. Maintenance service: if there is any quality problem with the products during the maintenance period, users can go to the local after-sales service center or entrust dealers to ask for maintenance service.
3. Matters Need Attention when install SPD:
A. Determine the discharge current path;
B. Mark the wires that produces an additional voltage drop on the device terminal;
C. Mark the PE conductor of each device to avoid unnecessary induction loops;
D. An equipotential connection is established between the device and SPD;
E. Multistage PSD energy coordination.
4. Why choose us:
A. We are reliable Alibaba Gold Supplier.
B. We are leading manufacturer in surge protective device for more than 5 years' experience.
C. Rich experience in Global market, export to more than 50 countries.
D. 100% QC inspection before shipment.
E. Keep research and development the latest technology.
F. Reply within 24 hours.
G. After sale service: Professional technical support.
H. Customized design: We can produce according to your request.