Arc Fault Circuit Breaker Disyuntor Afci/GFCI (AFCI)

Breaking Capacity: 6ka
Operation: Electric Type
Speed: High-Speed Circuit Breaker
Samples:
US$ 42.5/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Arc Fault Circuit Breaker Disyuntor Afci/GFCI (AFCI) pictures & photos
Arc Fault Circuit Breaker Disyuntor Afci/GFCI (AFCI)
US $39.5-42.5 / Piece
Min. Order: 5 Pieces
Gold Member Since 2024

Suppliers with verified business licenses

Secured Trading Service
Zhejiang, China
  • Overview
  • Product Description
  • Company Information
  • Our Services
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
XHAFLE-63 C32
Arc-extinguishing Medium
Air
Installation
Fixed
Structure
MCB
Poles Number
2
Type
Fault Arc Protection
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
VDE, ISO9001-2000, CE, CB, CCC
Rated Working Voltage(Ue)
AC 230V/AC 110V 50/60Hz
Rated Current of Tripper(in)
6, 10, 16, 20, 25, 32, 40, 50, 63A
Poles
1pn/2p
Impact Withstand Voltage(Uimp)
4kv
Short Circuit Breaking Capacity(ICU)
6ka
Instantaneous Trip
Type B, C, D
Electrical Life
≥3000 Operating Cycle
Mounting
Amounting Type
Compliance Standards
IEC En62606, IEC En61009
Leakage Trip
Electronic Type
Bcd Curve
C
Rated Frequency
50/60Hz
Connection Terminal
Screw Terminal / Pillar Terminal with Calmp
Connection Capacity
Rigid Conductor up to 25mm²
Fastening Torque
2.0nm
Transport Package
Standard Export Carton
Specification
40X33X30cm
Trademark
XHWellSpec
Origin
Zhejiang, China
HS Code
8536300000
Production Capacity
500000pieces Per Year

Packaging & Delivery

Package Size
10.00cm * 10.00cm * 10.00cm
Package Gross Weight
1.000kg
Lead Time
21 days (1 - 1 Pieces)
To be negotiated ( > 1 Pieces)

Product Description

Product Description
  circuit breakers,miniature circuit breaker,breaker circuit,electrical circuit breakers,dc circuit breaker,siemens circuit breakers,circuit breaker prices,mcb circuit breakers, circuit breaker,wifi circuit breaker,air circuit breaker,circuit breaker tester,marine circuit breaker 12v,12v circuit breaker,abb circuit breaker,circuit breaker amp,circuit breaker siemens,high voltage circuit breaker,arc fault circuit breaker,amp circuit breaker,chint electric circuit breaker,circuit breaker mcb,dc mcb miniature circuit breaker,isolating circuit breaker,circuit breaker elecbuy circuit breaker,trical,sf6 circuit breaker,changeover circuit breaker,circuit breaker box,rccb circuit breaker,100 amp circuit breakers,circuit breaker lockout,circuit breaker eaton hkd3400,merlin gerin circuit breaker,moulded case circuit breake,home voltage stabilizer with circuit breaker,power circuit breaker,power circuit breaker,circuit breaker types,vacuum circuit breaker,buy circuit breaker,three phase circuit breaker,eaton circuit breaker,motorized circuit breaker,thermal circuit breaker,smart circuit breaker,automatic circuit breaker

XHAFLE-63 C32 Arc Fault Circuit Interrupter(AFCI) is a new technology for circuit protection. Its main function is to detect and distinguish the dangerous ground arc fault, parallel arc fault and series arc fault, drive the device of current disconnection in time to avoid the occurrence of electrical fire. When an electrical fault occurs, due to the low current intensity, which is lower than the over-current protection installation setting value widely installed in the current system, especially in the low-voltage distribution field, the installation of a fault arc breaker at the distribution line terminal can timely detect the arc and cut off the circuit, effectively reducing the loss caused by the arc. The fault arc breaker is an intelligent circuit protector, an integrated design of MCB and RCB, which can detect and identify the fault arc in the circuit and the arc in normal operation. To prevent fire hazard caused by faulty electric arc due to poor contact and insulation in electrical circuit. It is a circuit protection device integrating fault arc protection, overload protection, short circuit protection, surge suppression and leakage protection. 

 

1. Application

The fault arc breakers are mainly installed in the distribution box of the terminal distribution system, and can also be installed in the control circuit units of home and office, all kinds of large supermarkets, department stores, hospitals, airports, textile mills, warehouses, oil depots, oil refineries, entertainment places, hotels, oil pipelines and so on. Wherever electricity is used, the device must be installed and used widely for electrical fire protection. 

2. Features: 

1.Protection against arc fault, overload and short circuit, the function of isolation
2.High short circuit capacity
3.Pin/fork type busbar terminal connecting
4.18mm DIN rail mounting and screw mounting
5. Full range accessories are available.

6. Flame-redardant: PA66 nylon material.

7. Protection degree: IP20.

8. Enduring termperature: 30°C.

9. Breaking Capacity: 6KA.

 

  

3. Technical Data:

 

Type
XHAFLE-63 C32
Poles
1PN/2P
Rated current
6, 10, 16, 20, 25, 32, 40, 50, 63A
Rated voltage
AC 230V/AC 110V 50/60Hz
Characteristic capacity
4.5KA/6KA
Electrical life
6000times
Impact Withstand Voltage(Uimp)
4kV
Tropicalizes
Treatment 2
Curve
B,C,D
Certificate
CE, GB
Standards
IEC 60898-1
Rated impulse withstand voltage
4.5kA/6kA
Connection terminal
Screw terminal / Pillar terminal with calmp
Connection capacity
Rigid conductor up to 25mm²
Fastening torque
2.0Nm
Installation
On symmetrical DIN rail 35mm / Panel mounting

Arc Fault Circuit Breaker Disyuntor Afci/GFCI (AFCI)

  

Arc Fault Circuit Breaker Disyuntor Afci/GFCI (AFCI)Arc Fault Circuit Breaker Disyuntor Afci/GFCI (AFCI)Arc Fault Circuit Breaker Disyuntor Afci/GFCI (AFCI)Arc Fault Circuit Breaker Disyuntor Afci/GFCI (AFCI)Arc Fault Circuit Breaker Disyuntor Afci/GFCI (AFCI)

Company Information
 Arc Fault Circuit Breaker Disyuntor Afci/GFCI (AFCI)Arc Fault Circuit Breaker Disyuntor Afci/GFCI (AFCI)Arc Fault Circuit Breaker Disyuntor Afci/GFCI (AFCI)Arc Fault Circuit Breaker Disyuntor Afci/GFCI (AFCI)
Our Services

 Arc Fault Circuit Breaker Disyuntor Afci/GFCI (AFCI)

Packaging & Shipping

 Arc Fault Circuit Breaker Disyuntor Afci/GFCI (AFCI)

FAQ

 

1. Working Conditions:

A. Ambient air temperature: -40oC~+125C, the highest monthly mean temperature should not exceed +35oC;

B. Altitude for installing place should not exceed 2000m; 

C. Atmospheric relative humidity: + 40  not more than 50%, the highest humidity is 90%, air relative humidity of 85% or less;

D. Pollution level: level 2;

 

2. Quality Assurance of Our Arc Fault Protectors:

A. We use molded material with excellent flame-retardant, good insulation performance and high temperature resistance characters.

B. We adopt thick galvanized sheet copper, it avoids the defects of conductive thread easily slip teeth.

C. The new design structure is aesthetic and compact size, good appearance and effective.

D. High sensitivity, long lifetime, good reliability and stability.

E. 100% Inspection before shipment.

 

3. Why choose us:

A. We are reliable Alibaba Gold Supplier.

B. We are leading manufacturer in circuit breakers for more than 10 years' experience.

C. Rich experience in Global market, export to more than 50 countries.

D. 100% QC inspection before shipment.

E. Keep research and development the latest technology.

F. Reply within 24 hours.

G. After sale service: Professional technical support.

H. Customized design: We can produce according to your request.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Arc Fault Circuit Breaker Disyuntor Afci/GFCI (AFCI) pictures & photos
Arc Fault Circuit Breaker Disyuntor Afci/GFCI (AFCI)
US $39.5-42.5 / Piece
Min. Order: 5 Pieces
Gold Member Since 2024

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Registered Capital
580000 RMB
Plant Area
>2000 square meters